--- /dev/null
+/**
+ * Copyright (c) 2017, Daniel Imms (MIT License).
+ * Copyright (c) 2018, Microsoft Corporation (MIT License).
+ */
+
+declare module 'node-pty' {
+ /**
+ * Forks a process as a pseudoterminal.
+ * @param file The file to launch.
+ * @param args The file's arguments as argv (string[]) or in a pre-escaped CommandLine format
+ * (string). Note that the CommandLine option is only available on Windows and is expected to be
+ * escaped properly.
+ * @param options The options of the terminal.
+ * @see CommandLineToArgvW https://msdn.microsoft.com/en-us/library/windows/desktop/bb776391(v=vs.85).aspx
+ * @see Parsing C++ Comamnd-Line Arguments https://msdn.microsoft.com/en-us/library/17w5ykft.aspx
+ * @see GetCommandLine https://msdn.microsoft.com/en-us/library/windows/desktop/ms683156.aspx
+ */
+ export function spawn(file: string, args: string[] | string, options: IPtyForkOptions | IWindowsPtyForkOptions): IPty;
+
+ export interface IBasePtyForkOptions {
+
+ /**
+ * Name of the terminal to be set in environment ($TERM variable).
+ */
+ name?: string;
+
+ /**
+ * Number of intial cols of the pty.
+ */
+ cols?: number;
+
+ /**
+ * Number of initial rows of the pty.
+ */
+ rows?: number;
+
+ /**
+ * Working directory to be set for the slave program.
+ */
+ cwd?: string;
+
+ /**
+ * Environment to be set for the slave program.
+ */
+ env?: { [key: string]: string };
+
+ /**
+ * String encoding of the underlying pty.
+ * If set, incoming data will be decoded to strings and outgoing strings to bytes applying this encoding.
+ * If unset, incoming data will be delivered as raw bytes (Buffer type).
+ * By default 'utf8' is assumed, to unset it explicitly set it to `null`.
+ */
+ encoding?: string | null;
+
+ /**
+ * (EXPERIMENTAL)
+ * Whether to enable flow control handling (false by default). If enabled a message of `flowControlPause`
+ * will pause the socket and thus blocking the slave program execution due to buffer back pressure.
+ * A message of `flowControlResume` will resume the socket into flow mode.
+ * For performance reasons only a single message as a whole will match (no message part matching).
+ * If flow control is enabled the `flowControlPause` and `flowControlResume` messages are not forwarded to
+ * the underlying pseudoterminal.
+ */
+ handleFlowControl?: boolean;
+
+ /**
+ * (EXPERIMENTAL)
+ * The string that should pause the pty when `handleFlowControl` is true. Default is XOFF ('\x13').
+ */
+ flowControlPause?: string;
+
+ /**
+ * (EXPERIMENTAL)
+ * The string that should resume the pty when `handleFlowControl` is true. Default is XON ('\x11').
+ */
+ flowControlResume?: string;
+ }
+
+ export interface IPtyForkOptions extends IBasePtyForkOptions {
+ /**
+ * Security warning: use this option with great caution, as opened file descriptors
+ * with higher privileges might leak to the slave program.
+ */
+ uid?: number;
+ gid?: number;
+ }
+
+ export interface IWindowsPtyForkOptions extends IBasePtyForkOptions {
+ /**
+ * Whether to use the ConPTY system on Windows. When this is not set, ConPTY will be used when
+ * the Windows build number is >= 18309 (instead of winpty). Note that ConPTY is available from
+ * build 17134 but is too unstable to enable by default.
+ *
+ * This setting does nothing on non-Windows.
+ */
+ useConpty?: boolean;
+
+ /**
+ * Whether to use PSEUDOCONSOLE_INHERIT_CURSOR in conpty.
+ * @see https://docs.microsoft.com/en-us/windows/console/createpseudoconsole
+ */
+ conptyInheritCursor?: boolean;
+ }
+
+ /**
+ * An interface representing a pseudoterminal, on Windows this is emulated via the winpty library.
+ */
+ export interface IPty {
+ /**
+ * The process ID of the outer process.
+ */
+ readonly pid: number;
+
+ /**
+ * The column size in characters.
+ */
+ readonly cols: number;
+
+ /**
+ * The row size in characters.
+ */
+ readonly rows: number;
+
+ /**
+ * The title of the active process.
+ */
+ readonly process: string;
+
+ /**
+ * (EXPERIMENTAL)
+ * Whether to handle flow control. Useful to disable/re-enable flow control during runtime.
+ * Use this for binary data that is likely to contain the `flowControlPause` string by accident.
+ */
+ handleFlowControl: boolean;
+
+ /**
+ * Adds an event listener for when a data event fires. This happens when data is returned from
+ * the pty.
+ * @returns an `IDisposable` to stop listening.
+ */
+ readonly onData: IEvent<string>;
+
+ /**
+ * Adds an event listener for when an exit event fires. This happens when the pty exits.
+ * @returns an `IDisposable` to stop listening.
+ */
+ readonly onExit: IEvent<{ exitCode: number, signal?: number }>;
+
+ /**
+ * Adds a listener to the data event, fired when data is returned from the pty.
+ * @param event The name of the event.
+ * @param listener The callback function.
+ * @deprecated Use IPty.onData
+ */
+ on(event: 'data', listener: (data: string) => void): void;
+
+ /**
+ * Adds a listener to the exit event, fired when the pty exits.
+ * @param event The name of the event.
+ * @param listener The callback function, exitCode is the exit code of the process and signal is
+ * the signal that triggered the exit. signal is not supported on Windows.
+ * @deprecated Use IPty.onExit
+ */
+ on(event: 'exit', listener: (exitCode: number, signal?: number) => void): void;
+
+ /**
+ * Resizes the dimensions of the pty.
+ * @param columns THe number of columns to use.
+ * @param rows The number of rows to use.
+ */
+ resize(columns: number, rows: number): void;
+
+ /**
+ * Writes data to the pty.
+ * @param data The data to write.
+ */
+ write(data: string): void;
+
+ /**
+ * Kills the pty.
+ * @param signal The signal to use, defaults to SIGHUP. This parameter is not supported on
+ * Windows.
+ * @throws Will throw when signal is used on Windows.
+ */
+ kill(signal?: string): void;
+ }
+
+ /**
+ * An object that can be disposed via a dispose function.
+ */
+ export interface IDisposable {
+ dispose(): void;
+ }
+
+ /**
+ * An event that can be listened to.
+ * @returns an `IDisposable` to stop listening.
+ */
+ export interface IEvent<T> {
+ (listener: (e: T) => any): IDisposable;
+ }
+}